AD8495 thermocouple amplifier - Type K, -200 to +1372 °C
This goes with it
Description
Product overview
- Amplifier module for Type K thermocouples with analog output
- Measurement range -200 °C to +1372 °C
- Resolution 0.25 °C
- Analog output 0–5 V at full scale
- Output voltage proportional to the measured temperature
- Integrated cold-junction compensation
- Connection via 3.3 V or 5 V logic
Product description
The module converts the minimal voltages of a Type K thermocouple into a linear analog signal. Thermocouple amplifiers of this type typically process only millivolt signals, which is why an amplifier stage is necessary. Cold-junction compensation automatically detects the reference temperature, eliminating the need for manual calibration or an external reference junction.
The 0–5 V output voltage range is compatible with standard ADC inputs on common microcontroller boards. This allows temperatures to be converted directly into sensor readings. The amplifier module operates with 3.3 V or 5 V logic and can be connected to common development boards.
Applications include high-temperature process monitoring in industry and skilled trades (ovens, furnaces, melting systems), material testing in laboratory environments, and temperature measurement in thermal experiments. Those who need extremely broad measurement ranges, from the freezing point to the range of industrial process heat, will find a proven measurement method here.
A thermocouple must be purchased separately. The connection cable from the sensor to the module should be made of copper and kept short to avoid amplification errors. The module outputs raw values; conversion to Celsius temperature is performed by the connected microcontroller.
Safety information
The module is intended exclusively for building prototypes and for testing and development purposes. It is not designed for operation on household electrical installations or for installation in finished devices. Work on or in the immediate vicinity of high-temperature processes or electrical systems must be carried out by qualified electricians; if in doubt, consult a qualified electrician before commissioning.
Scope of delivery
- 1x AD8495 ARMZ / CJMCU-8495 thermocouple amplifier for Type K thermocouples