MH-Z19C CO2 sensor - NDIR infrared, 400-5000 ppm, UART and PWM
This goes with it
incl. VAT, plus shipping
Description
MH-Z19C (Pin) - NDIR CO2 sensor with UART and PWM output
The MH-Z19C (Pin) is a compact CO2 sensor based on the non-dispersive infrared (NDIR) measurement principle. It detects the carbon dioxide concentration in the air and operates independently of oxygen.
The sensor features integrated temperature compensation and provides measurements via UART or PWM. Compared with its predecessor, the MH-Z19B, the preheating time has been reduced from 3 minutes to 1 minute and power consumption has been optimized.
Highlights
- NDIR measurement principle for detecting CO2
- Measurement range of 400 to 5000 ppm
- UART and PWM output
- Integrated temperature compensation
- Oxygen-independent measurement
- Preheating time of just 1 minute
- Automatic calibration on a 24-hour cycle
- Automatic calibration can be turned on and off via command
- Manual zero-point calibration available
- Pin header with 2.54 mm pitch
CO2 measurement with NDIR technology
The MH-Z19C uses the NDIR principle to determine the CO2 concentration. With its integrated temperature compensation and oxygen-independent operation, the sensor is suitable for various air quality monitoring applications.
UART, PWM and calibration
Measurements can be output via UART or PWM. The UART output uses a TTL interface level of 3.3 V and is listed as 5 V compatible in the product specifications.
The sensor supports automatic calibration on a 24-hour cycle. This function can be turned on or off via command. Manual zero-point calibration can also be enabled.
Typical applications
- Indoor CO2 measurement
- Air quality monitoring
- Measurement and learning projects with microcontrollers
- Environmental and indoor climate projects
- Automation and monitoring applications
Technical specifications
| Category | Feature | Specification |
|---|---|---|
| Product | Model | MH-Z19C |
| Measurement | Target gas | CO2 |
| Measurement | Measurement range | 400 - 5000 ppm |
| Measurement | Accuracy | ± (40 ppm + 5% of reading) |
| Power supply | Operating voltage | 5 V DC (±0.1 V) |
| Power supply | Average current consumption | < 40 mA @ 5 V |
| Power supply | Peak current | 125 mA @ 5 V |
| Interface | Interface level | 3.3 V, 5 V compatible |
| Interface | Output signals | UART and PWM |
| Interface | UART level | TTL, 3.3 V |
| Operation | Preheating time | 1 minute |
| Operation | Response time T90 | < 120 s |
| Environment | Operating temperature | -10 - 50 °C |
| Environment | Operating humidity | 0 - 95% RH, non-condensing |
| Dimensions | Dimensions | Approx. 33 x 20 x 17 mm |
| Connection | Pin header | 2.54 mm pitch |
| Calibration | Automatic | Every 24 hours, can be turned on and off via command |
| Calibration | Manual | Zero-point calibration can be enabled |
Technical data
Advanced 19 specifications