MAX30102 pulse sensor - heart rate and SpO2, I2C
This goes with it
incl. VAT, plus shipping
Description
Product overview
- Combined sensor for heart rate and blood oxygen saturation (SpO2) using reflected red and infrared light
- I2C interface with interrupt output for event-driven data output
- Sensor IC: 1.7–2.0 V, LED supply: 3.1–5.0 V
- Internal FIFO memory for buffered readings
- Software-controlled shutdown with no standby current
- 14 * 14 mm board; finger must be placed on the sensor for measurement
Product description
The module measures heart rate and blood oxygen saturation simultaneously. Two LEDs (red and infrared) and a light sensor are mounted on a very small board. When you place a finger on the sensor, the light passes through the skin and is reflected back to varying degrees depending on blood flow and oxygen levels. An integrated analog-to-digital converter digitizes the light sensor's received signal.
The raw data is processed not on the module, but by a connected microcontroller via I2C. This interface allows you to configure the operating mode, LED brightness, and sampling rate, as well as read measurements from the internal FIFO memory. An additional interrupt output signals the microcontroller when new data is available, so it does not have to poll the bus continuously. The software then calculates pulse rate and oxygen level from fluctuations in the infrared and red light signals.
The sensor IC requires a supply voltage of 1.7–2.0 V, while the LEDs require 3.1–5.0 V, so both voltage levels must be provided. Software-controlled shutdown with no standby current also makes the module suitable for battery-powered applications. Typical projects include simple pulse monitors, fitness trackers, and setups for measuring blood oxygen optically.
The sensor requires direct finger contact for reliable readings. Operation requires a microcontroller with I2C support and evaluation software that calculates the medical measurements from the raw optical values.
Safety notice
The module's LEDs emit red and infrared light within a range considered safe for this application. However, you should avoid staring directly at the light sources for prolonged periods. The module is intended exclusively for prototyping, testing, and development, and is not designed for medical use or installation in household electrical circuits. Work on electrical installations must be carried out by a qualified electrician. If you have questions about correct integration, consult a qualified electrician before commissioning.
Scope of delivery
- 1* MAX30102 heart rate and SpO2 (blood oxygen) sensor module