AD620 voltage amplifier - instrumentation module, gain 1-10000
This goes with it
incl. VAT, plus shipping
Description
Product overview
- Instrumentation amplifier for small voltages, measuring range ±325 mV to ±2.5 V in four selectable voltage ranges
- Integrated IC with fixed gain or programmable gain using external resistors
- Supply voltage ±2.7 V to ±18 V or single-supply 5.4 V to 36 V
- Output voltage of 0 to +Vcc with single-supply or ±Vout with dual-supply
- Gain set using a resistor between pin 16 and pin 17; gain from 1 to 10000 achievable
- Internal reference voltage output (2.5 V) can be used to calibrate measured values
Product description
The AD620 is a signal amplifier for measuring very small voltages, such as those supplied by sensors or measurement interfaces. Its integrated instrumentation amplifier operates differentially: it detects the voltage difference between two inputs and amplifies only that, while suppressing interference on both lines (so-called common-mode noise). This makes the module ideal for applications where signals are transmitted over long cables or where there are multiple sources of interference in the environment.
The gain is controlled by the value of an external resistor; the internal circuit then determines the exact gain. A 100 kOhm resistor gives a gain of 100, while a 1-kOhm resistor gives a gain of 10000. The internal 2.5 V reference voltage can be used for sensor feedback, for example to power a transducer. The output is interpreted differently depending on the power supply (single-supply or dual-supply) and must be read using an appropriate analog-to-digital converter or similar circuit.
The amplifier is suitable for load cells and pressure sensors in weighing systems, humidity or temperature sensors using low-resistance measurement bridges, and biomedical sensors such as those used for ECG measurements. It is also commonly found in laboratory measurement setups, where it makes weak signals visible before they are digitized. A key feature is its relatively high input resistance, which places very little load on sensors.
The supply voltage is selected according to the project requirements. For battery operation, ±2.7 V is sufficient; in the lab, ±18 V is possible with bench power supplies. The output must be read using an analog-to-digital converter or a measurement module with a suitable input voltage. The exact gain requires calculating or measuring the external resistor, and is not calibration-free if the highest accuracy is required.
Safety notice
The module is intended exclusively for building prototypes and for testing and development purposes. It is not suitable for installation in household electrical circuits. When working on or near electrical installations, consult a qualified electrician; if in doubt, consult a qualified electrician before commissioning.
Scope of delivery
- 1x AD620 Voltage Amplifier Signal Instrumentation Module