PLC Coupler for DOBOT Magician - 8-channel, 24 V to 3.3 V
This goes with it
incl. VAT, plus shipping
Description
Funduino PLC coupler – safely connect Siemens PLCs and other 24V systems to the DOBOT Magician
The Funduino PLC coupler enables reliable, galvanically isolated coupling between a Siemens PLC with 24 V logic and the DOBOT Magician via its GP2 port or other available ports.
The module was specifically developed to safely connect industrial PLC signals to the DOBOT's 3.3 V I/O logic without risking damage to the robot.
Safe voltage conversion in both directions
Since the DOBOT Magician cannot tolerate 24 V signals, the Funduino PLC coupler incorporates two galvanically isolated optocouplers/level converters:
24 V → 3.3 V (4-channel)
PLC outputs can safely be connected to a digital input on the robot (e.g., a start signal).
3.3 V → 24 V (4-channel)
The robot can safely send status or completion signals back to the PLC.
This enables robust bidirectional communication between the PLC and robot without a direct electrical connection or risk of damage from overvoltage.
Designed for training, laboratories, and industrial education
The PLC coupler is ideal for:
- Training & instruction (PLC fundamentals, robotics integration)
- Technical labs & universities
- Industry-oriented training setups
- Educational demonstrations of handshake protocols
- Typical applications include start/complete signals, simple sequence control, or learning PLC-robot handshakes (start → action → feedback)
Easy integration via the GP2 port
The Funduino PLC coupler is designed for the manufacturer-recommended use of the EIO14 / EIO15 pins on the DOBOT Magician's GP2 port.
A pre-assembled 4-pin GP2 connector makes connection easier and reduces wiring errors.
All optocoupler channels are also available, for a total of 8 channels.
Highlights at a glance
- Safe 24 V ↔ 3.3 V level conversion
- Galvanic isolation to protect the PLC and robot
- Bidirectional communication (PLC → robot ↔ PLC)
- Ideal for Siemens PLCs (e.g., S7-1200)
- Compatible with DOBOT Magician (GP2 port)
- Ideal for training, education, and demonstrations
- Proven in practice with example handshake
What's included
1x Optocoupler module 24 V → 3.3 V (4-channel)
1x Optocoupler module 3.3 V → 24 V (4-channel)
1x Matching enclosure
2x Matching JST connectors for the Dobot Magician
1x Instructions with example program for the Dobot Magician
This is a kit. The wiring must be done according to the instructions.